Browse + Post a Listing

2x GE LM 2500 G4,DLE,

ReflowX SKU: REF-7455


Description

GE LM2500 G4 DLE Power Plant - 2 Units (2018)

Turbine Specifications:

  • Model: GE LM2500 G4 with Dry Low Emission (DLE) Technology
  • Power Output: 33.37 MW per turbine
  • Fuel Type: Dual Fuel (Natural Gas & Diesel)
  • Year: 2018
  • Hours: Zero hours (brand new, unused)
  • Voltage: 10.5 kV
  • Frequency: Dual Frequency (Supports both 50 Hz and 60 Hz operation)
  • Emission Technology: Dry Low Emission (DLE), reducing NOx emissions for environmental compliance
  • Cooling System: Air-cooled or water-cooled (depending on setup)

Complete Power Plant Package Scope:

This setup is a complete power plant, and it includes the following key components in addition to the turbines:

  1. Turbine and Generator Units:

    • 2 x GE LM2500 G4 DLE Gas Turbines (each 33.37 MW)
    • Alternators (to convert mechanical power into electrical power)
    • High-Voltage (HV) and Low-Voltage (LV) Cabinets for power distribution
  2. Cooling and Auxiliary Systems:

    • Coolers for turbine cooling
    • Lube Oil System to ensure smooth operation of the turbines
    • Gas and Water Treatment Systems to clean and prepare fuel and water used in the plant
    • HRSG (Heat Recovery Steam Generator): This system captures the exhaust heat from the turbines to produce steam, improving overall efficiency in a combined-cycle setup.
  3. Steam System:

    • 25 MW Steam Turbine: This additional steam turbine is used to further generate power by utilizing the steam produced by the HRSG.
    • Steam Turbine Alternator: Converts steam power into electrical power.
    • Steam Tank: Used to store and regulate steam flow.
  4. Combustion and Environmental Management:

    • Chimney: For exhaust emissions to be released safely into the atmosphere.
    • Firefighting System: Ensures safety by controlling potential fire hazards in the power plant.
  5. Electrical Systems:

    • Transformers: For voltage conversion to suitable levels for grid distribution.
    • MCC (Motor Control Center): For controlling electrical motors in the power plant.
    • High-Voltage (HV) Components: Including circuit breakers, protection relays, and switches for high-voltage operation.
  6. Control Systems:

    • Complete Control System: Includes both turbine and power plant control systems for efficient, automated operation.
    • High-Performance PLCs for control and monitoring of the entire system.
    • SCADA System: For remote monitoring and control, ensuring smooth operation and maintenance alerts.

Key Features of the Complete Power Plant:

  • Dual Fuel Operation: The system is equipped to run on both natural gas and diesel, providing flexibility and fuel security.
  • Zero Hours: These turbines and the entire plant are brand new, meaning zero hours of operation.
  • Combined-Cycle Efficiency: The setup includes both gas turbines and steam turbines, which allows for a combined-cycle configuration, increasing the overall efficiency of the plant by using exhaust heat to generate steam.
  • Environmental Compliance: Dry Low Emission (DLE) technology ensures reduced NOx emissions, making the plant environmentally friendly and compliant with strict emission standards.
  • Complete Turnkey Solution: The plant is a complete, turnkey power plant solution, including all the necessary components for operation, from turbines to transformers, cooling systems, control systems, and safety equipment.

Applications:

  • Utility-Scale Power Generation: This setup is ideal for base load or peak load power generation in industrial or utility-scale applications.
  • Flexible Power Supply: It can be used for areas requiring reliable, clean, and efficient power, with the option to switch between natural gas and diesel.
  • Combined-Cycle Applications: The combination of gas turbines and a steam turbine maximizes efficiency by utilizing the heat from the gas turbine exhaust for additional steam generation.

Summary of Specifications:

  • Model: GE LM2500 G4 DLE (2 units)
  • Power Output: 33.37 MW per turbine
  • Fuel Type: Dual Fuel (Natural Gas / Diesel)
  • Voltage: 10.5 kV
  • Frequency: Dual (50 Hz / 60 Hz)
  • Emission Technology: Dry Low Emission (DLE)
  • Total Plant Scope: Turbines, Alternators, Coolers, Lube System, Gas & Water Treatment, HRSG, Steam Turbine (25 MW), Chimney, Fire Fighting, Transformers, Control Panels
  • Year: 2018 (Brand New, Zero Hours)
  • Application: Utility, Industrial Power Generation, Combined Cycle
     

    For further specifications or to inquire about this equipment and ReflowX's logistics services, Please contact ReflowX at info@reflowx.com 


General Terms

  • ReflowX and the seller retain the right to evaluate and approve offers.
  • Buyers should verify quantities and conditions upon delivery.
  • After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
  • All parties agree to adhere to ReflowX Terms and Conditions in transactions.
  • Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!
ariba